USGS Banner
[Solar System] [Missions] [Technology] [Data & Information] [Research] [Hot Topics] [Gallery] [About Us] [Search]
 [end navigation bar]

Infrared Spectra of Dust Coatings

Mars Surface
Detailed experimental conditions for the coating experiments of basalts.
(See note on viewing and downloading files.)

Spectra files (.asc) are given in units of wavenumber (first column) and either emission or reflectance (second column; valid values ranging from 0 to 1). See accompanying manuscripts (above) for details on useful spectral ranges in each spectral data set.
Coating Substrate Coating Thickness
(µm ± standard deviation)
Emissivity Reflectance
none Basaltic Andesite
0 (plot , spectra)
0 (plot , spectra)
JSC-1 Basaltic Andesite
19 ± 6 (plot , spectra)
17 ± 9 (plot , spectra)
JSC-1 Basaltic Andesite
41 ± 20 (plot , spectra)
27 ± 11 (plot , spectra)
JSC-1 Basaltic Andesite
46 ± 12 (plot , spectra)
42 ± 16 (plot , spectra)
JSC-1 Basaltic Andesite
49 ± 23 (plot , spectra)
61 ± 24 (plot , spectra)
JSC-1 Basaltic Andesite
68 ± 24 (plot , spectra)
81 ± 27 (plot , spectra)
JSC-1 Basaltic Andesite
93 ± 27 (plot , spectra)
105 ± 34 (plot , spectra)
JSC-1 Basaltic Andesite
149 ± 49 (plot , spectra)
122 ± 41 (plot , spectra)
JSC-1 Basaltic Andesite
2000 (plot , spectra)
2000 (plot , spectra)
Pahala Ash Basaltic Andesite
18 ± 4 (plot , spectra)
16 ± 11 (plot , spectra)
Pahala Ash Basaltic Andesite
29 ± 7 (plot , spectra)
21 ± 13 (plot , spectra)
Pahala Ash Basaltic Andesite
32 ± 8 (plot , spectra)
24 ± 10 (plot , spectra)
Pahala Ash Basaltic Andesite
34 ± 14 (plot , spectra)
47 ± 21 (plot , spectra)
Pahala Ash Basaltic Andesite
50 ± 12 (plot , spectra)
54 ± 22 (plot , spectra)
Pahala Ash Basaltic Andesite
54 ± 24 (plot , spectra)
67 ± 19 (plot , spectra)
Pahala Ash Basaltic Andesite
99 ± 26 (plot , spectra)
104 ± 30 (plot , spectra)
Pahala Ash Basaltic Andesite
2000 (plot , spectra)
2000 (plot , spectra)
Redart clay Basaltic Andesite
19 ± 7 (plot , spectra)
14 ± 13 (plot , spectra)
Redart clay Basaltic Andesite
28 ± 11 (plot , spectra)
23 ± 19 (plot , spectra)
Redart clay Basaltic Andesite
35 ± 12 (plot , spectra)
31 ± 15 (plot , spectra)
Redart clay Basaltic Andesite
49 ± 16 (plot , spectra)
47 ± 24 (plot , spectra)
Redart clay Basaltic Andesite
93 ± 31 (plot , spectra)
55 ± 15 (plot , spectra)
Redart clay Basaltic Andesite
2000 (plot , spectra)
2000 (plot , spectra)
Ball clay OM-4 Basaltic Andesite
18 ± 6 (plot , spectra)
18 ± 15 (plot , spectra)
Ball clay OM-4 Basaltic Andesite
23 ± 7 (plot , spectra)
39 ± 29 (plot , spectra)
Ball clay OM-4 Basaltic Andesite
29 ± 13 (plot , spectra)
50 ± 35 (plot , spectra)
Ball clay OM-4 Basaltic Andesite
55 ± 20 (plot , spectra)
65 ± 37 (plot , spectra)
Ball clay OM-4 Basaltic Andesite
2000 (plot , spectra)
2000 (plot , spectra)
Loess Basaltic Andesite
19 ± 15 (plot , spectra)
24 ± 11 (plot , spectra)
Loess Basaltic Andesite
28 ± 18 (plot , spectra)
30 ± 16 (plot , spectra)
Loess Basaltic Andesite
41 ± 23 (plot , spectra)
53 ± 22 (plot , spectra)
Loess Basaltic Andesite
63 ± 22 (plot , spectra)
72 ± 21 (plot , spectra)
Loess Basaltic Andesite  
95 ± 30 (plot , spectra)
Loess Basaltic Andesite
2000 (plot , spectra)
2000 (plot , spectra)
12000µm is used to designate spectra of pure coated material.

Return to top of page

ASD Reflectance Spectra
(See note on viewing and downloading files.)

Spectra files (.asc) are given in units of nanometers (first column) and reflectance (second column; valid values ranging from 0 to 1).
Coating Substrate Coating Thicknes
(µm ± std. dev.)
none Basaltic Andesite
0 (plot , spectra)
JSC-1 Basaltic Andesite
17 ± 9 (plot , spectra)
JSC-1 Basaltic Andesite
19 ± 8 (plot , spectra)
JSC-1 Basaltic Andesite
27 ± 11 (plot , spectra)
JSC-1 Basaltic Andesite
42 ± 16 (plot , spectra)
JSC-1 Basaltic Andesite
53 ± 26 (plot , spectra)
JSC-1 Basaltic Andesite
61 ± 24 (plot , spectra)
JSC-1 Basaltic Andesite
81 ± 27 (plot , spectra)
JSC-1 Basaltic Andesite
106 ± 34 (plot , spectra)
JSC-1 Basaltic Andesite
122 ± 41 (plot , spectra)
JSC-1 Basaltic Andesite
20001 (plot , spectra)
12000µm is used to designate spectra of pure coated material.


Return to top of page